Please Note: The Clearway 2 is available to order, but lead times for delivery are currently 2-4 weeks
Introducing the new Clearway 2 with TreatRepeat® The second-generation MI-E device by Breas incorporates the latest technology to bring effective and accurate treatment for patients requiring airway clearance and cough assistance. TreatRepeat function allows you to manually deliver different numbers of insufflations and exsufflations and then save the treatment they have just delivered to the device to be repeated automatically. Helping to improve accuracy and speed of titration and set-up.
Please note the hand controller is an optional extra when purchasing the Clearway 2 Cough Assist.
ADVANCED TITRATION TECHNOLOGY
- Unique to the Clearway 2 – TreatRepeat®
- Intuitive touchscreen user interface
- Hand-held remote manual switch with start/stop function
MULTIPLE MODE OPTIONS
- Programmable automatic modes
ENHANCED PATIENT SYNCHRONY
- TreatRepeat® to help improve accuracy and speed of titration and set-up
- iTrigger® − built on the Breas patented eSync algorithm
- Synchrony Beep® to aid patient-device synchrony
Settings / Performance
Modes
Manual, Basic Auto, Program Mode, IPPB, NIV
Device Modes
Home, Clinical (Locked/Unlocked)
Profiles
4 settable profiles
Insufflation Pressure
3 cm H2O to 70 cm H2O
Exsufflation Pressure
−3 cm H2O to −70 cm H2O
Insufflation Time
0.5 to 5 seconds
Exsufflation Time
0.5 to 5 seconds
Pause Time
0.5 to 5 seconds
Flow Options (MI-E)
1−10 (10−100% of Ti max 4 seconds)
Flow (IPPB)
20 L/min to 120 L/min
Inspiratory Trigger
Off or 1 to 10
Oscillations Frequency
Insufflations and or Exsufflations, Off – 1 – 20 Hz
Oscillations Amplitude
1 cm H2O to 10 cm H2O
Monitoring
Displayed Data
Cough Peak Flow, Insufflation Volume, Pressure, Flow, SpO2, Heart Rate Sessions Used, Average Session Duration
Waveforms
Pressure
Trend and Statistical Data via PC Software
Cough Peak Flow, Insufflation Volume, Use, SpO2, Heart Rate
Power Supplies
Mains Supply
100 to 240 V AC
Internal Battery
>30 min in MI-E modes (based on settings of +40/ -45cmH2O, Ti/Te/P 2 seconds)
Main Alarms
Alarms
Circuit Disconnection, Running on Battery Power, External Battery Fault, High Pressure Alarm, Internal Over Temperature Alarm, Low Battery, Low Memory Battery, Machine Fault, Low SPO2 Reading, High SO2 SpO2 Sensor Disconnect, High/Low Heart Rate, Power Fail
Dimensions
W x H x D
285 x 285 x 195 mm
Weight
3.85 kg
Noise Level (at 10 cm H2O Constant Pressure)
Sound Level at 70 cm H2O in Manual Mode Less Than 74 dB(A) Measured at 1 meter
Connectivity and Software
Built-in Connectivity
Ethernet, USB, SD card
Compatible Software
Prepared for Breas Cloud Service
Plug-and-Play Accessories
SpO2, Hand Held Remote Start/Stop and Manual Switch, Manual Foot Pedal Switch
Other
Circuits
Disposable circuit with bacterial filter no leak port for MI-E modes and disposable circuit with bacterial filter and leak port for IPPB and NIV modes