{"product_id":"masimo-rad-97-pulse-co-oximeter","title":"Masimo Rad 97 Pulse CO-Oximeter","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Masimo Rad-97 is a compact, portable bedside pulse oximeter designed for continuous, non-invasive monitoring of oxygen saturation and pulse rate. It uses Masimo SET® Measure-through Motion and Low Perfusion™ technology, helping provide dependable readings when patients are moving or have weak peripheral perfusion.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIts high-resolution colour touchscreen can be customised to display the most clinically relevant measurements, waveforms and trends. Automatic screen rotation, ambient-light brightness adjustment and colour-coded adult, paediatric and neonatal profiles make the monitor suitable for a wide range of clinical environments.\u003c\/p\u003e\n\u003cp\u003eThe standard Rad-97 displays SpO₂, pulse rate, perfusion index and Pleth Variability Index. It can also be configured or upgraded with Masimo rainbow® measurements, subject to the installed software, compatible patient cable and appropriate sensors.\u003c\/p\u003e\n\u003ch3\u003eMain features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eContinuous SpO₂ and pulse-rate monitoring\u003c\/li\u003e\n\u003cli\u003eMasimo SET® motion and low-perfusion performance\u003c\/li\u003e\n\u003cli\u003eHigh-resolution colour multi-touch display\u003c\/li\u003e\n\u003cli\u003eAutomatic screen rotation and brightness adjustment\u003c\/li\u003e\n\u003cli\u003ePlethysmographic waveform display\u003c\/li\u003e\n\u003cli\u003eAdult, paediatric and neonatal profiles\u003c\/li\u003e\n\u003cli\u003eUp to 96 hours of trend data\u003c\/li\u003e\n\u003cli\u003eAdjustable audible and visual alarms\u003c\/li\u003e\n\u003cli\u003eRechargeable internal battery\u003c\/li\u003e\n\u003cli\u003eBuilt-in Wi-Fi, Ethernet, USB, Bluetooth Low Energy and nurse-call connectivity\u003c\/li\u003e\n\u003cli\u003eSuitable for mounting on an optional mobile roll stand\u003c\/li\u003e\n\u003cli\u003eOptional versions incorporating NIBP or NomoLine® capnography\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandard measurements\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMeasurement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO₂\u003c\/td\u003e\n\u003ctd\u003eFunctional arterial oxygen saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePR\u003c\/td\u003e\n\u003ctd\u003ePulse rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePI\u003c\/td\u003e\n\u003ctd\u003ePerfusion Index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePVi®\u003c\/td\u003e\n\u003ctd\u003ePleth Variability Index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eUpgradeable measurements\u003c\/h3\u003e\n\u003cp\u003eAvailability depends on the monitor’s configuration, licences, cables and sensors.\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eMeasurement\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpHb®\u003c\/td\u003e\n\u003ctd\u003eNon-invasive total haemoglobin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpCO®\u003c\/td\u003e\n\u003ctd\u003eCarboxyhaemoglobin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpMet®\u003c\/td\u003e\n\u003ctd\u003eMethaemoglobin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpOC™\u003c\/td\u003e\n\u003ctd\u003eOxygen content\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORi®\u003c\/td\u003e\n\u003ctd\u003eOxygen Reserve Index\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRRa®\u003c\/td\u003e\n\u003ctd\u003eAcoustic respiration rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRRp®\u003c\/td\u003e\n\u003ctd\u003eRespiration rate derived from the pleth waveform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eTechnical specification\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO₂ measurement range\u003c\/td\u003e\n\u003ctd\u003e0–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStated SpO₂ accuracy range\u003c\/td\u003e\n\u003ctd\u003e70–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO₂ accuracy, no motion\u003c\/td\u003e\n\u003ctd\u003e±2% adults, paediatrics and infants; ±3% neonates\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO₂ accuracy during motion\u003c\/td\u003e\n\u003ctd\u003e±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpO₂ accuracy at low perfusion\u003c\/td\u003e\n\u003ctd\u003e±2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-rate range\u003c\/td\u003e\n\u003ctd\u003e25–240 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-rate accuracy, no motion\u003c\/td\u003e\n\u003ctd\u003e±3 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-rate accuracy during motion\u003c\/td\u003e\n\u003ctd\u003e±5 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePulse-rate accuracy at low perfusion\u003c\/td\u003e\n\u003ctd\u003e±3 bpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpHb range\u003c\/td\u003e\n\u003ctd\u003e8–17 g\/dL; stated accuracy ±1 g\/dL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpCO range\u003c\/td\u003e\n\u003ctd\u003e1–40%; stated accuracy ±3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpMet range\u003c\/td\u003e\n\u003ctd\u003e1–15%; stated accuracy ±1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRRa\/RRp range\u003c\/td\u003e\n\u003ctd\u003e4–70 respirations per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrend memory\u003c\/td\u003e\n\u003ctd\u003eUp to 96 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution colour LCD multi-touch display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eRechargeable lithium-ion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate battery runtime\u003c\/td\u003e\n\u003ctd\u003eUp to 7 hours under specified low-power conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproximate charging time\u003c\/td\u003e\n\u003ctd\u003e3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e110–220 V AC, 47–63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.9 × 16.5 × 10.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eLess than 1.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to 35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure\u003c\/td\u003e\n\u003ctd\u003e540–1,060 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection rating\u003c\/td\u003e\n\u003ctd\u003eIP21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplied part\u003c\/td\u003e\n\u003ctd\u003eType BF, defibrillation-proof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating mode\u003c\/td\u003e\n\u003ctd\u003eContinuous operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eWi-Fi, Bluetooth LE, Ethernet, USB and nurse-call interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Masimo UK Ltd","offers":[{"title":"Default Title","offer_id":56853635924354,"sku":"9738","price":1908.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0625\/5640\/5965\/files\/image_6ebe35d2-531d-4bb8-938c-700dedde2153.png?v=1787059890","url":"https:\/\/nebulisersdirect.co.uk\/products\/masimo-rad-97-pulse-co-oximeter","provider":"Nebulisers Direct","version":"1.0","type":"link"}